No tracking number?
15mm SV Plate to Plate Radiographic Testing RT Flawed Specimens (As per BINDT PCN Classification Specimens) 15mm SV Plate to Plate Radiographic Testing Flawed Specimens-RT Geometry: Plate to Plate Single V Butt Weld 300 mm Long and 150 mm Wide on Either Side of The Weld thickness Range >10 mm to 15mm. Material: Carbon Steel Flaws: 3 per specimen, randomly placed Specimen Tolerance: +/- 0.080" Documentation: NDT Verification Reports,C of C, CAD Drawings and Test Sheets RT Report. (Customized Calibration Test Block and Flaw Specimen also available. Contact- info@ndetech.org.in)
20mm DV Plate to Plate Radiography Testing RT Flawed Specimens (As per BINDT PCN Classification Specimens) 20mm DV Plate to Plate Radiography Testing Flawed Specimens-RT Geometry: Plate to Plate Double V Butt Weld 300mm Long and 150 mm Wide on Either Side of The Weld thickness 20 mm. Material: Carbon Steel. Flaws: 3 per specimen, randomly placed Specimen Tolerance: +/- 0.080" Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets RT Report. (Customized Calibration Test Block and Flaw Specimen also available. Contact- info@ndetech.org.in)
20mm SV Plate to Plate Radiography Testing RT Flawed Specimens (As per BINDT PCN Classification Specimens) 20mm SV Plate to Plate Radiography Testing Flawed Specimens-RT Geometry: Plate to Plate Single V Butt Weld 300mm Long and 150 mm Wide on Either Side of The Weld thickness 20 mm. Material: Carbon Steel. Flaws: 3 per specimen, randomly placed Specimen Tolerance: +/- 0.080". Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets RT Report. (Customized Calibration Test Block and Flaw Specimen also available. Contact- info@ndetech.org.in)
25mm DV Plate to Plate RT Flawed Specimens- Radiography Testing (As per BINDT PCN Classification Specimens) 25mm DV Plate to Plate RT Flawed Specimens-Radiography Testing Geometry: Plate to Plate Double V Butt Weld 300 mm Long and 150 mm Wide on Either Side of The Weld thickness 25 mm. Material: Carbon Steel. Flaws: 3 per specimen, randomly placed Specimen Tolerance: +/- 0.080" Documentation: NDT Verification Reports,C of C, CAD Drawings and Test Sheets RT Report. (Customized Calibration Test Block and Flaw Specimen also available. Contact- info@ndetech.org.in)
25mm SV Plate to Plate RT Flawed Specimens- Radiographic Testing (As per BINDT PCN Classification Specimens) 25mm SV Plate to Plate RT Flawed Specimens- Radiographic Testing Geometry: Plate to Plate Single V Butt Weld 300 mm Long and 150 mm Wide on Either Side of The Weld and Plate thickness 25 mm. Material: Carbon Steel Flaws: 3 per specimen, randomly placed Specimen Tolerance: +/- 0.080" Documentation: NDT Verification Reports,C of C, CAD Drawings and Test Sheets RT Report. (Customized Calibration Test Block and Flaw Specimen also available. Contact- info@ndetech.org.in)
3” Butt Weld Joint Pipe RT Flawed Specimens-Radiography Testing Radiographic Testing (As per BINDT PCN Classification Specimens) 3” Butt Weld Joint Pipe Radiography Testing Flawed Specimens-RT Geometry: Pipe to Pipe Butt Weld Joint with Pipe 3”Dia. And 150 mm Wide on Either Side of The Weld thickness 12mm Material: Carbon Steel Flaws: 3 per specimen, randomly placed Specimen Tolerance: +/- 0.080" Documentation: NDT Verification Reports,C of C, CAD Drawings and Test Sheets RT Report. (Customized Calibration Test Block and Flaw Specimen also available. Contact- info@ndetech.org.in)
4” Butt Weld Joint Pipe RT Flawed Specimens-Radiography Testing (As per BINDT PCN Classification Specimens) 4” Butt Weld Joint Pipe Radiography Testing Flawed Specimens-RT Geometry: Pipe to Pipe Butt Weld Joint with Pipe 4” Dia. And 150 mm Wide on Either Side of The Weld thickness 15 mm. Material: Carbon Steel Flaws: 3 per specimen, randomly placed Specimen Tolerance: +/- 0.080" Documentation: NDT Verification Reports,C of C, CAD Drawings and Test Sheets RT Report. (Customized Calibration Test Block and Flaw Specimen also available. Contact- info@ndetech.org.in)
6” Butt Weld Joint Pipe Radiography Testing Flawed Specimens-Radiographic Testing (As per BINDT PCN Classification Specimens) 6” Butt Weld Joint Pipe Radiography Testing Flawed Specimens-RT Geometry: Pipe to Pipe Butt Weld Joint with Pipe 6”Dia. And 150 mm Wide on Either Side of The Weld thickness 20 mm Material: Carbon Steel Flaws: 3 per specimen, randomly placed Specimen Tolerance: +/- 0.080" Documentation: NDT Verification Reports,C of C, CAD Drawings and Test Sheets RT Report. (Customized Calibration Test Block and Flaw Specimen also available. Contact- info@ndetech.org.in)
T Joint 15mm SV Plate to Plate RT Flawed Specimens-Radiography Testing (As per BINDT PCN Classification Specimens) T Joint 15mm SV Plate to Plate Radiography Testing Flawed Specimens-RT Geometry: Plate to Plate T Joint Single V Butt Weld with 300 mm Long and 200 mm Wide base and 150mm Wide t Plate in the Thickness Range of 12 mm to 15 mm Material: Carbon Steel Flaws: 3 per specimen, randomly placed Specimen Tolerance: +/- 0.080" Documentation: NDT Verification Reports,C of C, CAD Drawings and Test Sheets RT Report. (Customized Calibration Test Block and Flaw Specimen also available. Contact- info@ndetech.org.in)
NdeTech Was Established In 2012 As NDT Based Company. Our Portfolio Spans Across Industrial Services And Manufacturing Sectors. NdeTech Was Established As NDT&E Reference Standards And Flawed Weld Specimens Manufacturing Company, And NDT Training Certification, Recruitment Consultant For Inspection Industries Provider To Cater The Requirements Of Various Industries In India As Well As Abroad.
2024 NDETECH All Right Reserved.