No tracking number?
AWS STRUCTURAL VT KIT (Inch Version) Carbon Steel AWS Visual Kit (Based on AWS D1.1) • Kit is designed specifically for VT Weld Inspection. Flaws are designed to be “Border Line” Acceptable or Reject able. • Material: Carbon Steel • Kit contains 10 specimens: • Flaws are randomly placed • (4) Tees 4″ (L) x 6″ (W) x 2″ (H) x 0.25″ (T) • (4) Plates 4″ (L) x 6″ (W) x 0.25″ (T) • (2) Pipe: Ø4” Sch40 (0.25” wall) x 6” (L) • Flaws: at least 2 per specimen, 25 total • Welding Process – SMAW • Document Package Includes: Certificate of Conformance, CAD Drawings & Test Sheets
AWS STRUCTURAL VT KIT (Metric Version) Carbon Steel AWS Visual Kit (Based on AWS D1.1) • Kit is designed specifically for VT Weld Inspection. Flaws are designed to be “Border Line” Acceptable or Reject able. • Material: Carbon Steel • Kit contains 10 specimens: • Flaws are randomly placed • (4) Tees 4″ (L) x 6″ (W) x 2″ (H) x 0.25″ (T) • (4) Plates 4″ (L) x 6″ (W) x 0.25″ (T) • (2) Pipe: Ø4” Sch40 (0.25” wall) x 6” (L) • Flaws: at least 2 per specimen, 25 total • Welding Process – SMAW • Document Package Includes: Certificate of Conformance, CAD Drawings & Test Sheets
Cast Specimen Set (Inch) Qty: 1 Set of 8 Specimens Specifications: • Each Cast Specimen Set will contain a mix of 8 aluminum cast specimens. There will be limited specimen geometry duplication. • The specimens are nominal in size and can be held easily in one hand. • Each specimen will contain a variety of visual casting defects and abnormalities. • There is not a standard number of casting defects per specimen. • Each specimen is a unique casting and cannot be duplicated. • NDE Flaw Tech will call out the obvious indications. • The skilled inspector may observe indications not documented by NDE Flaw Tech. Cast Specimen Sets Documentation: • Includes a photograph of each of the 8 specimen’s major surface or side. • Each photograph will include one or more call outs indicating the location of the prominent defect(s). • Each specimen major side will be hard stamped 1A, 1B, 2A, 2B, thru 8A, 8B. Carrying Case Dimensions and Kit Weight: • 38cm x 33cm x 25cm, ~8KGS
Cast Specimen Set (Metric) Qty: 1 Set of 8 Specimens Specifications: • Each Cast Specimen Set will contain a mix of 8 aluminum cast specimens. There will be limited specimen geometry duplication. • The specimens are nominal in size and can be held easily in one hand. • Each specimen will contain a variety of visual casting defects and abnormalities. • There is not a standard number of casting defects per specimen. • Each specimen is a unique casting and cannot be duplicated. • NDE Flaw Tech will call out the obvious indications. • The skilled inspector may observe indications not documented by NDE Flaw Tech. Cast Specimen Sets Documentation: • Includes a photograph of each of the 8 specimen’s major surface or side. • Each photograph will include one or more call outs indicating the location of the prominent defect(s). • Each specimen major side will be hard stamped 1A, 1B, 2A, 2B, thru 8A, 8B. Carrying Case Dimensions and Kit Weight: • 38cm x 33cm x 25cm, ~8KGS
“The Traveler” CWI Visual Training Kit (Inch Version) NDE Flaw Tech’s new polymer specimen set developed specifically for CWI training and testing. Efficiently designed to provide a maximum number of indications with minimal weight to support the traveling CWI instructor. Kit Specifications: • Material, polyurethane (gray color) • Designed to be very lightweight for ease of transport • 15 specimens, (6) Plates, (3) Tee Joints & (6) 180° Pipe Segments • Flaws / Indications, ~3 to 4 per specimen for a total of 50+ weld indications. • Specimens also contain various weld bevels and flame cut edges • All indications are based on AWS D1.1 • Carrying Case, 1 @ 20” x 18” x 10”; fits all 15 samples • Weight ~11KGS Please note the flaws / indications are intended to be “borderline” acceptable or rejectable. The end user (CWI) must make that determination. Documentation: • Includes Certificate of Conformance, CAD drawings & Test Sheets (Optional: Weld Size and CAM Gauges)
“The Traveler Ⅱ” CWI Visual Training Bend Kit (Inch Version) Qty: 1 Kit Specifications: • Material, polyurethane (gray color) • Designed to be very light weight for ease of transport. • 4 specimens, • 2 Side Bend specimens with 4 bends each for a total of 8 Side Bends. • 2 Longitudinal Bend specimens with 4 bends each for a total of 8 Longitudinal Bends. • All welds are a nominal Single V Groove bevel. • Flaws / Indications, each specimen contains approximately ~3 to 5 indications for a total of 15+ indications. Some bends have no flaws. • Please note the flaws / indications are intended to be “borderline” acceptable or rejectable. The end user (CWI) must make that determination. • These specimens can be used in conjunction with the following codes; AWS D1.1 & D1.5, ASME and API weld inspection. • Carrying Case, 1 @ 51cm x 46cm x 25cm • Weight ~10 KGS Documentation: • Includes C of C, CAD drawings & Test Sheets
“The Traveler Ⅱ” CWI Visual Training Bend Kit (Metric Version) Qty: 1 Kit Specifications: • Material, polyurethane (gray color) • Designed to be very light weight for ease of transport. • 4 specimens, • 2 Side Bend specimens with 4 bends each for a total of 8 Side Bends. • 2 Longitudinal Bend specimens with 4 bends each for a total of 8 Longitudinal Bends. • All welds are a nominal Single V Groove bevel. • Flaws / Indications, each specimen contains approximately ~3 to 5 indications for a total of 15+ indications. Some bends have no flaws. • Please note the flaws / indications are intended to be “borderline” acceptable or rejectable. The end user (CWI) must make that determination. • These specimens can be used in conjunction with the following codes; AWS D1.1 & D1.5, ASME and API weld inspection. • Carrying Case, 1 @ 51cm x 46cm x 25cm • Weight ~10 KGS Documentation: • Includes C of C, CAD drawings & Test Sheets
“The Traveler” CWI Visual Training Kit (Metric Version) NDE Flaw Tech’s new polymer specimen set developed specifically for CWI training and testing. Efficiently designed to provide a maximum number of indications with minimal weight to support the traveling CWI instructor. Kit Specifications: • Material, polyurethane (gray color) • Designed to be very lightweight for ease of transport • 15 specimens, (6) Plates, (3) Tee Joints & (6) 180° Pipe Segments • Flaws / Indications, ~3 to 4 per specimen for a total of 50+ weld indications. • Specimens also contain various weld bevels and flame cut edges • All indications are based on AWS D1.1 • Carrying Case, 1 @ 51cm x 46cm x 25cm; fits all 15 samples • Weight ~11KGS Please note the flaws / indications are intended to be “borderline” acceptable or rejectable. The end user (CWI) must make that determination. Documentation: • Includes Certificate of Conformance, CAD drawings & Test Sheets (Optional: Weld Size and CAM Gauges)
2020 NDETECH All Right Reserved.